Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Br J Pharmacol ; 175(4): 606-617, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29181850

RESUMO

BACKGROUND AND PURPOSE: Translation of non-clinical markers of delayed ventricular repolarization to clinical prolongation of the QT interval corrected for heart rate (QTc) (a biomarker for torsades de pointes proarrhythmia) remains an issue in drug discovery and regulatory evaluations. We retrospectively analysed 150 drug applications in a US Food and Drug Administration database to determine the utility of established non-clinical in vitro IKr current human ether-à-go-go-related gene (hERG), action potential duration (APD) and in vivo (QTc) repolarization assays to detect and predict clinical QTc prolongation. EXPERIMENTAL APPROACH: The predictive performance of three non-clinical assays was compared with clinical thorough QT study outcomes based on free clinical plasma drug concentrations using sensitivity and specificity, receiver operating characteristic (ROC) curves, positive (PPVs) and negative predictive values (NPVs) and likelihood ratios (LRs). KEY RESULTS: Non-clinical assays demonstrated robust specificity (high true negative rate) but poor sensitivity (low true positive rate) for clinical QTc prolongation at low-intermediate (1×-30×) clinical exposure multiples. The QTc assay provided the most robust PPVs and NPVs (ability to predict clinical QTc prolongation). ROC curves (overall test accuracy) and LRs (ability to influence post-test probabilities) demonstrated overall marginal performance for hERG and QTc assays (best at 30× exposures), while the APD assay demonstrated minimal value. CONCLUSIONS AND IMPLICATIONS: The predictive value of hERG, APD and QTc assays varies, with drug concentrations strongly affecting translational performance. While useful in guiding preclinical candidates without clinical QT prolongation, hERG and QTc repolarization assays provide greater value compared with the APD assay.


Assuntos
Fármacos Cardiovasculares/farmacologia , Drogas em Investigação/farmacologia , Canais de Potássio Éter-A-Go-Go/fisiologia , Frequência Cardíaca/efeitos dos fármacos , Potenciais de Ação/efeitos dos fármacos , Potenciais de Ação/fisiologia , Fármacos Cardiovasculares/uso terapêutico , Avaliação Pré-Clínica de Medicamentos/métodos , Drogas em Investigação/uso terapêutico , Canais de Potássio Éter-A-Go-Go/agonistas , Canais de Potássio Éter-A-Go-Go/antagonistas & inibidores , Frequência Cardíaca/fisiologia , Humanos , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/fisiopatologia , Estudos Retrospectivos , Torsades de Pointes/tratamento farmacológico , Torsades de Pointes/fisiopatologia
3.
Am J Trop Med Hyg ; 81(2): 356-62, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19635898

RESUMO

A randomized, double-blind, placebo-controlled study was conducted to assess the effect of tafenoquine, 200 mg weekly for 6 months on ophthalmic and renal safety. This trial was carried out after observations in previous clinical trials that tafenoquine may be associated with the development of corneal deposits and elevations in serum creatinine. In 120 healthy volunteers who received tafenoquine or placebo in a 2:1 randomization, there was no effect on night vision or other ophthalmic indices measured. Persons taking tafenoquine also showed no difference in mean change in glomerular filtration rate (GFR, mL/s/1.73 m(2)) after 6 months of dosing, with a treatment difference of -0.061 (95% confidence interval, -0.168, 0.045), and non-inferiority margin of -0.247 mL/s/1.73 m(2). Tafenoquine was well tolerated over the course of the study. The results of this study showed no clinically significant effects of tafenoquine on ophthalmic or renal function, and support its continued development as an antimalarial drug.


Assuntos
Aminoquinolinas/efeitos adversos , Antimaláricos/efeitos adversos , Oftalmopatias/induzido quimicamente , Nefropatias/induzido quimicamente , Visão Noturna/efeitos dos fármacos , Adolescente , Adulto , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
4.
Artigo em Inglês | MEDLINE | ID: mdl-17599846

RESUMO

A simple and sensitive HPLC-UV assay was developed for the measurement of iothalamate (IOT) in human serum and urine. Chromatographic separation was achieved using an embedded-carbamate-group bonded RP18 column and mobile phase consisting of 50 mM monobasic sodium phosphate and methanol (90:10, v/v) without the addition of ion-pair reagents. The assay demonstrated a high analytical reliability within the IOT concentration range of 1-150 microg/ml in serum and 25-1500 microg/ml in urine. The relative standard deviations (RSDs) for intra- and inter-day analysis were less than 5.1% in all cases. This method has been used for the evaluation of glomerular filtration rate (GFR) in subjects participating in a phase I clinical trial of a novel antimalarial medicine. The average baseline GFR was 100.41+/-19.99 ml/min/1.73 m(2) in 119 healthy volunteers. The assay may also allow the simultaneous measurements of p-aminohippuric acid (PAH), N-acetyl PAH (aPAH), and IOT with some modification. PAH, IOT, aPAH, and beta-hydroxyethyl-theophylline internal standard peaks appeared approximately at 2.5, 3.7, 5.9, and 11.8 min, respectively, in an isocratic run.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Taxa de Filtração Glomerular , Ácido Iotalâmico/análise , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Anal Toxicol ; 30(1): 21-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16620527

RESUMO

A rapid and highly sensitive gas chromatography-mass spectrometry (GC-MS) method for simultaneous determination of N,N-diethyl-m-toluamide (DEET) and permethrin with (2)H(10)-phenanthrene (98 atom %) as an internal standard and a separate external standard high-performance liquid chromatography (HPLC) method for pyridostigmine bromide (PB) determination in human plasma were developed and validated. The GC-MS method for DEET and permethrin quantification utilizes a one-step extraction with tert-butylmethylether. The HPLC method for PB quantification involves a solid-phase extraction and UV detection. The range of the analytical method for DEET and permethrin was 1 ng/mL to 100 ng/mL and for PB was 5 ng/mL to 100 ng/mL. Recovery from plasma proved to be more than 80%. The intraday precision ranged from 1.3% to 8% for DEET, from 2.1% to 11.4% for permethrin, and from 3.0% to 4.8% for PB. The interday precision was 3% for DEET, ranged from 5% to 9% for permethrin, and from 5% to 9% for PB. The accuracy for the limit of quantification was 92% +/- 8% relative standard deviation (RSD) for DEET, 112% +/- 11% RSD for permethrin, and 109% +/- 5% RSD for PB. All 3 compounds were stable in human plasma at -80 degrees C for at least 12 months and after 2 freeze-thaw cycles with RSD values ranging from 7.1% (DEET, 80 ng/mL) to 8.1% (DEET, 8 ng/mL), from 2.3% (permethrin, 80 ng/mL) to 11.6 % (permethrin, 8 ng/mL), and from 0.2% (PB, 80 ng/mL) to 3.6% (PB, 8 ng/mL). Both methods were successfully applied to pharmacokinetic/ pharmacodynamic studies of combined exposure of DEET (skin application), permethrin (treated uniforms), and PB (30 mg orally three times/day for four doses) in healthy volunteers (n = 81).


Assuntos
Cromatografia Líquida de Alta Pressão , DEET/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Repelentes de Insetos/sangue , Inseticidas/sangue , Permetrina/sangue , Brometo de Piridostigmina/sangue , DEET/farmacocinética , Estabilidade de Medicamentos , Humanos , Repelentes de Insetos/farmacocinética , Inseticidas/farmacocinética , Medicina Militar , Permetrina/farmacocinética , Brometo de Piridostigmina/farmacocinética , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...